Gas and Air Quality Sensors
Gas and air-quality sensors are used to detect or measure gases and other pollutants present in the surrounding environment.
They are important in:
- Gas leakage detection
- Smoke detection
- Indoor air-quality monitoring
- Industrial safety
- Smart homes
- Agriculture
- Environmental monitoring
- IoT systems
- Fire and safety systems
A basic system works like this:
Gas / Pollutant ↓ Sensor ↓ Electrical Signal ↓ Arduino / ESP32 ↓ Processing ↓ Display / Alarm / Notification
1. What is a Gas Sensor?
A gas sensor is a device that detects the presence or concentration of a particular gas or group of gases.
For example:
- LPG
- Methane
- Carbon monoxide (CO)
- Carbon dioxide (CO₂)
- Alcohol vapors
- Smoke
- Volatile organic compounds (VOCs)
A gas sensor can be used simply for detection, or for estimating concentration.
2. What is Air Quality?
Air quality describes how clean or polluted the air is.
Poor air quality can result from pollutants such as:
- Smoke
- Carbon monoxide
- Nitrogen oxides
- Sulfur dioxide
- VOCs
- Fine particulate matter
Different pollutants require different sensing technologies.
Therefore:
There is no single sensor that perfectly measures every aspect of air quality.
3. Gas Detection vs Gas Measurement
These are two different concepts.
Gas detection
Answers:
"Is gas present?"
Example:
Gas detected → YES Gas detected → NO
Gas measurement
Attempts to determine:
"How much gas is present?"
Example:
CO concentration = 25 ppm
Accurate concentration measurement generally requires a properly calibrated sensor and controlled measurement conditions.
4. MQ-Series Gas Sensors
The MQ series is very popular in Arduino and ESP32 projects.
Common examples include:
- MQ-2
- MQ-3
- MQ-4
- MQ-5
- MQ-6
- MQ-7
- MQ-9
- MQ-135
These sensors generally use a heated sensing element whose electrical resistance changes when exposed to certain gases.
5. How MQ Sensors Work
A typical MQ sensor contains:
Gas-sensitive material + Heater
Conceptually:
Gas enters ↓ Sensing material reacts ↓ Resistance changes ↓ Electrical output changes ↓ Microcontroller reads signal
The sensor's resistance changes according to the surrounding gas environment.
6. MQ-2
MQ-2 is one of the most common gas sensor modules used in beginner projects.
It is sensitive to gases/vapors such as:
- LPG
- Smoke
- Methane
- Propane
- Hydrogen
- Some other combustible gases
A typical project:
MQ-2 ↓ ESP32 ↓ Gas threshold check ↓ Buzzer ↓ Alarm
7. MQ-3
The MQ-3 is commonly associated with detecting alcohol vapors.
It can be used in educational projects involving:
- Alcohol vapor detection
- Breath-related demonstrations
- Safety experiments
However, an MQ-3 module should not be treated as a certified breathalyzer without proper calibration and controlled measurement.
8. MQ-4
The MQ-4 is commonly used for detecting methane/natural gas-related environments.
Applications can include:
- Gas leakage demonstrations
- Industrial monitoring prototypes
- Gas detection systems
9. MQ-5
MQ-5 is commonly used for detecting combustible gases such as:
- LPG
- Natural gas
- Hydrogen
It is often used in gas leakage detection projects.
10. MQ-6
MQ-6 is particularly associated with LPG and butane/propane-related gas detection.
A typical application:
Gas Leakage ↓ MQ-6 ↓ ESP32 ↓ Alarm
11. MQ-7
The MQ-7 is designed for carbon monoxide (CO) sensing.
CO is a dangerous gas because it is:
- Colorless
- Odorless
- Potentially toxic
A CO detection system can therefore be used for safety monitoring.
However, hobby MQ modules should not replace certified life-safety CO alarms.
12. MQ-9
MQ-9 is commonly used for detecting gases including:
- Carbon monoxide
- Methane
- LPG
- Other combustible gases
The exact sensitivity depends on operating conditions and sensor characteristics.
13. MQ-135
The MQ-135 is frequently used in hobby projects for general air-quality-related sensing.
It is sensitive to various gases, including certain:
- Ammonia-related vapors
- Smoke
- CO₂-related environments
- Alcohol vapors
- Other gases
However, an important point is:
MQ-135 is not a direct, calibrated CO₂ meter.
Its output is affected by multiple gases, temperature, humidity, sensor aging, and other environmental factors.
14. MQ Sensor Comparison
| Sensor | Common Target/Use |
|---|---|
| MQ-2 | Smoke, LPG, methane, combustible gases |
| MQ-3 | Alcohol vapors |
| MQ-4 | Methane / natural gas |
| MQ-5 | LPG / natural gas / hydrogen |
| MQ-6 | LPG / butane / propane |
| MQ-7 | Carbon monoxide |
| MQ-9 | CO and combustible gases |
| MQ-135 | General air-quality-related sensing |
These are typical applications, not exclusive gas identification capabilities.
15. Analog Output
Many MQ modules provide an analog output.
Conceptually:
Gas concentration/exposure ↓ Sensor resistance changes ↓ Voltage changes ↓ Analog output ↓ ADC ↓ Microcontroller
An ESP32 can read the analog voltage using an ADC-capable GPIO.
16. Digital Output
Many MQ modules also include a comparator circuit that provides a digital output.
For example:
Gas level below threshold → LOW Gas level above threshold → HIGH
The threshold can often be adjusted using a potentiometer on the module.
Therefore, the module may have:
VCC GND AO → Analog Output DO → Digital Output
17. Analog vs Digital MQ Output
Analog
Provides a continuously varying voltage.
Gas exposure ↓ Analog voltage ↓ ADC
Useful when you want to observe changes in sensor response.
Digital
Provides a simple threshold result.
Sensor ↓ Comparator ↓ LOW / HIGH
Useful for simple alarm projects.
18. Important: ESP32 Voltage Safety
This is especially important when using MQ modules with an ESP32.
Many MQ modules are designed around 5 V operation, and their analog/digital outputs may reach voltages that are not suitable for direct connection to an ESP32 GPIO.
ESP32 GPIOs are generally 3.3 V logic.
Therefore:
MQ Module ↓ Check output voltage ↓ If output can exceed ESP32 limit ↓ Use appropriate voltage divider / level shifting ↓ ESP32 GPIO
Never assume that an MQ module's output is automatically safe for an ESP32 just because the sensor is being used in an IoT project.
19. MQ Sensor Heater
MQ sensors contain an internal heater.
The heater is important because it helps the sensing material operate correctly.
Therefore:
MQ Sensor ├── Heater └── Gas-sensitive element
The heater consumes power.
This means MQ sensors can consume significantly more power than many modern low-power digital environmental sensors.
20. Warm-Up Time
MQ sensors generally need a warm-up period.
Immediately after powering the sensor:
Power ON ↓ Heater warms up ↓ Sensor stabilizes ↓ Measurement becomes more useful
A short-term reading immediately after power-on may not be reliable.
For serious measurement applications, the sensor should be conditioned according to its datasheet and calibration procedure.
21. Calibration
Calibration is one of the most important concepts in gas sensing.
Suppose:
Actual condition → Known reference Sensor output → Measured response
We can determine how the sensor behaves under known conditions.
For MQ sensors, the relationship between sensor resistance and gas concentration is not simply:
Voltage = Gas concentration
Instead, the response is influenced by several factors.
22. Factors Affecting MQ Sensors
MQ readings can be affected by:
- Temperature
- Humidity
- Sensor aging
- Heater voltage
- Supply voltage
- Different gases
- Sensor-to-sensor variation
- Warm-up state
- Airflow
- Contamination
Therefore:
An MQ sensor's raw ADC value should not automatically be interpreted as an accurate ppm value.
23. What is PPM?
PPM = Parts Per Million
It is commonly used to express very small gas concentrations.
For example:
100 ppm
means approximately:
100 parts of gas per 1,000,000 parts of the mixture
But obtaining a reliable ppm measurement requires appropriate calibration and sensor modeling.
24. Gas Sensor System
A simple gas detection system can be designed as:
GAS SENSOR ↓ Analog Signal ↓ ESP32 ↓ Threshold Check ↓ ┌─────┴─────┐ ↓ ↓ Safe Level Gas Alert ↓ Buzzer / LED ↓ Mobile Alert
25. Example: LPG Leakage Detection
Imagine a kitchen gas leakage detector.
LPG Leakage ↓ MQ-6 ↓ ESP32 ↓ Gas level exceeds threshold ↓ Buzzer ON ↓ LED ON ↓ Send notification
The system could display:
------------------------ GAS MONITOR ------------------------ Status: GAS DETECTED! Alarm: ON ------------------------
For real household safety, use a certified gas detector appropriate for the specific gas and installation environment rather than relying solely on a hobby module.
26. Smoke Detection
An MQ-2 can be used in educational smoke-detection projects.
Smoke ↓ MQ-2 ↓ ESP32 ↓ Threshold ↓ Alarm
For actual fire safety, use certified smoke alarms designed and tested for life-safety applications.
27. CO Detection
A CO sensor can be used to monitor carbon monoxide.
CO ↓ CO Sensor ↓ Microcontroller ↓ Alarm
Because CO is dangerous, certified CO alarms should be used for real residential protection.
28. CO₂ Sensors
CO₂ is different from CO.
CO → Carbon Monoxide CO₂ → Carbon Dioxide
They are completely different gases.
A commonly used technology for CO₂ measurement is NDIR.
NDIR = Non-Dispersive Infrared
Examples of NDIR CO₂ sensors include families such as:
- Sensirion SCD30/SCD4x
- Senseair sensors
- Other dedicated CO₂ modules
29. How NDIR CO₂ Sensors Work
CO₂ absorbs infrared radiation at characteristic wavelengths.
An NDIR sensor uses this principle:
Infrared Source ↓ Gas Cell ↓ CO₂ absorbs specific IR wavelengths ↓ Optical Detector ↓ Processing ↓ CO₂ concentration
This is fundamentally different from the heated metal-oxide sensing used in many MQ sensors.
30. VOC Sensors
VOC = Volatile Organic Compounds
VOCs can come from:
- Paint
- Solvents
- Cleaning products
- Fuels
- Adhesives
- Building materials
- Human activities
Some modern environmental sensors can estimate VOC-related air-quality information.
Examples include:
- BME680
- BME688
- SGP30
- SGP40
These sensors generally provide a sensor response or estimated air-quality/VOC-related metric rather than identifying every individual VOC molecule.
31. Particulate Matter Sensors
Gas sensors and particulate sensors are different.
Particulate matter (PM) refers to tiny particles suspended in air.
Examples:
- PM1.0
- PM2.5
- PM10
Sensors such as the PMS5003 or similar optical particle sensors can estimate particulate concentration.
Basic operation:
Air ↓ Particles enter sensor ↓ Laser / optical scattering ↓ Photodetector ↓ Particle estimation ↓ PM reading
32. Gas vs Particulate Sensor
| Sensor Type | Measures |
|---|---|
| MQ sensor | Gas-related response |
| NDIR sensor | Specific gas such as CO₂ |
| VOC sensor | VOC-related response |
| PM sensor | Airborne particles |
| BME280 | Temperature, humidity, pressure |
| BME680/BME688 | Environmental parameters + gas resistance |
Therefore:
Air Quality │ ├── Gases ├── VOCs ├── CO₂ └── Particulate Matter
Different sensors are needed for different measurements.
33. Air Quality Monitoring System
A more advanced system can combine multiple sensors:
AIR QUALITY SYSTEM │ ┌──────────────┼──────────────┐ ↓ ↓ ↓ CO₂ VOC PM2.5 Sensor Sensor Sensor │ │ │ └──────────────┼──────────────┘ ↓ ESP32 ↓ Wi-Fi / Cloud ↓ Dashboard
The dashboard could display:
----------------------------- AIR QUALITY ----------------------------- CO₂ : 720 ppm VOC : Normal PM2.5 : 18 µg/m³ Status : Good -----------------------------
The exact "good/bad" classification should be based on the appropriate standard and measurement method rather than arbitrary thresholds.
34. Gas Sensors in Smart Homes
A smart home can monitor:
- LPG leakage
- Smoke
- CO
- CO₂
- VOCs
- Particulate matter
Example:
Gas Sensor ↓ ESP32 ↓ Wi-Fi ↓ Mobile App
If a dangerous condition is detected:
Sensor ↓ ESP32 ↓ Alarm ↓ Notification
35. Industrial Applications
Gas sensors are important in industrial environments.
They can be used for:
- Gas leakage monitoring
- Worker safety
- Combustible gas detection
- Process monitoring
- Environmental monitoring
Industrial systems may use specialized sensors such as:
- Electrochemical sensors
- Catalytic bead sensors
- Infrared sensors
- Photoionization detectors
- Metal-oxide semiconductor sensors
The choice depends on the gas and required accuracy.
36. Electrochemical Gas Sensors
Electrochemical sensors are commonly used for gases such as:
- CO
- O₂
- H₂S
- SO₂
- NO₂
Basic concept:
Gas ↓ Electrochemical Cell ↓ Chemical Reaction ↓ Electrical Current ↓ Measurement Circuit
They are often more suitable than hobby MQ sensors when selective gas measurement is required.
37. Infrared Gas Sensors
Infrared techniques can be used to detect gases based on their absorption of specific wavelengths.
For example:
Gas ↓ IR Absorption ↓ Optical Detector ↓ Concentration Estimation
NDIR CO₂ sensors are a common example.
38. Metal-Oxide Semiconductor Sensors
Many MQ sensors use a metal-oxide semiconductor sensing material.
Its electrical resistance changes when exposed to certain gases.
Gas ↓ Metal-Oxide Surface ↓ Resistance Change ↓ Electrical Signal
This technology is relatively inexpensive but can have:
- Cross-sensitivity
- Temperature dependence
- Humidity dependence
- Long-term drift
39. Important Difference: Detection vs Certified Safety
This is extremely important.
A hobby project:
MQ-2 + ESP32 + Buzzer
is excellent for:
- Learning
- Demonstration
- Prototyping
- Understanding gas sensing
But it should not automatically be considered a certified safety system.
For real-life protection from:
- CO
- LPG
- Fire
- Toxic gases
use appropriate certified detectors and safety equipment.
40. Example ESP32 Gas Detection
For an analog gas module, conceptually:
#define GAS_SENSOR 34 #define BUZZER 23 void setup() { Serial.begin(115200); pinMode(BUZZER, OUTPUT); } void loop() { int value = analogRead(GAS_SENSOR); Serial.print("Gas Sensor: "); Serial.println(value); if (value > 2000) { digitalWrite(BUZZER, HIGH); Serial.println("WARNING: Gas level increased!"); } else { digitalWrite(BUZZER, LOW); } delay(500); }
The value 2000 here is only an example threshold for programming practice. It is not a universal gas-safety threshold.
41. Better Gas Monitoring Logic
Instead of immediately triggering an alarm from one reading, a more robust system can use multiple readings:
Read sensor ↓ Filter noise ↓ Compare with calibrated threshold ↓ Confirm condition ↓ Trigger alarm
For example:
Gas level high ↓ Wait / verify ↓ Still high? ↓ YES ↓ Alarm
This can reduce false alarms caused by temporary fluctuations.
42. Common Problems
1. No Warm-Up
MQ sensors require proper warm-up.
2. Treating Raw ADC as PPM
This is one of the most common mistakes.
ADC = 2500
does not automatically mean:
2500 ppm
3. Ignoring Humidity and Temperature
Environmental conditions can significantly affect sensor response.
4. Wrong Power Supply
MQ heaters can consume substantial current.
5. Connecting 5 V Output Directly to ESP32
Check the output voltage before connecting it to a 3.3 V GPIO/ADC.
6. Using Hobby Sensors as Safety Devices
A prototype is not necessarily a certified safety instrument.
43. Complete Gas and Air Quality System
A more advanced IoT system can look like:
AIR ENVIRONMENT │ ┌─────────────┼─────────────┐ ↓ ↓ ↓ MQ Sensor CO₂ Sensor PM Sensor │ │ │ └─────────────┼─────────────┘ ↓ ESP32 ↓ Data Processing ↓ ┌───────┴───────┐ ↓ ↓ Display Wi-Fi ↓ Cloud / App
This is a practical architecture for an IoT air-quality monitoring system.
Key Points to Remember
Gas Sensors
Detect or estimate the presence/concentration of gases.
Important technologies
MQ Series ↓ Metal-Oxide Semiconductor Electrochemical ↓ Chemical reaction → Electrical signal NDIR ↓ Infrared absorption Optical PM ↓ Light scattering → Particle estimation
Common sensors
MQ-2 → Smoke / combustible gases MQ-3 → Alcohol vapors MQ-4 → Methane MQ-5 → LPG / natural gas MQ-6 → LPG-related sensing MQ-7 → CO MQ-135 → General air-quality-related sensing
Modern environmental sensors
BME680 / BME688 → Temperature + Humidity + Pressure + Gas resistance SCD30 / SCD4x → CO₂ SGP30 / SGP40 → VOC-related sensing PMS5003 → Particulate matter
Most important concept
Gas ↓ Sensor ↓ Electrical / Optical Response ↓ Microcontroller ↓ Processing + Calibration ↓ Measurement / Alarm / IoT