Ugenz Academy/IoT Tutorial

Transformers

15 min read2,840 words

Reading progress

Keep learning

Transformers — Complete Detailed Explanation

1. What Is a Transformer?

A transformer is an electrical device that transfers electrical energy from one circuit to another through electromagnetic induction. It is mainly used to increase or decrease AC voltage and current without changing the frequency.

Transformers operate on the principle of mutual induction.

A transformer usually consists of two coils of wire wound around a common magnetic core:

  • Primary winding: The coil connected to the input AC supply.
  • Secondary winding: The coil from which the output is taken.
  • Magnetic core: Provides a path for the magnetic flux linking both windings.

Transformatorene er strømnettets skjulte kraftkarer | Tu.no

tu.no

For example, a transformer can convert 230 V AC into 12 V AC for use in a low-voltage power supply.

Important: A conventional transformer requires a changing magnetic field, so it normally operates with AC, not steady DC.

2. Why Do We Need Transformers?

Transformers are essential because electrical devices and power systems require different voltage levels.

Their main purposes are:

  1. Increasing voltage: To transmit electrical power over long distances with lower current and reduced transmission losses.
  2. Decreasing voltage: To provide a lower, safer voltage for electronic circuits and electrical equipment.
  3. Electrical isolation: To separate two circuits electrically while transferring energy magnetically.
  4. Impedance matching: To help match the impedance of a source to a load in certain electronic and audio circuits.
  5. Voltage adjustment: To provide the required AC voltage for a particular application.

For example, a power supply may receive 230 V AC from a wall outlet and use a step-down transformer to produce 12 V AC. Additional rectifier and regulator circuits can then convert this into suitable DC for electronic devices.

3. Construction of a Transformer

What Are Internal Components of an Electrical Transformer?

cnc-power.com

A transformer has several important parts.

A. Primary Winding

The primary winding is the coil connected to the AC input supply.

When AC flows through this winding, it creates a changing magnetic field around the coil.

The number of turns in the primary winding is represented by NpN_p.

B. Secondary Winding

The secondary winding is the coil connected to the output circuit or load.

The changing magnetic field induces a voltage in this winding.

The number of turns in the secondary winding is represented by NsN_s.

C. Magnetic Core

The core provides a low-reluctance path for magnetic flux, allowing the magnetic field to link both windings efficiently.

Transformer cores are commonly made from laminated silicon steel in power-frequency transformers. High-frequency transformers often use ferrite cores.

D. Insulation

Insulation separates the windings from each other and from the core where necessary. It prevents unwanted electrical contact and helps ensure safe operation.

E. Transformer Housing and Cooling

Larger transformers may include a protective tank, cooling fins, insulating oil, bushings, and other components. Small electronic transformers may simply use an insulated enclosure.

These parts protect the transformer, help dissipate heat, and provide electrical connections.

4. Working Principle of a Transformer

A transformer works through Faraday’s law of electromagnetic induction and mutual induction.

The operation can be understood in the following steps.

How to Choose the Right Electric Transformer for Your Needs

Step 1: AC supply is applied

An alternating voltage is applied to the primary winding. This causes an alternating current to flow through the primary circuit.

How to Make a Transformer: Engineering Principles and Best Practices

Step 2: Magnetic flux is produced

The alternating current creates a changing magnetic field. The magnetic core guides the changing magnetic flux through both windings.

Faraday’s Laws of Electromagnetic Induction | Definition, Formula

Step 3: Voltage is induced

The changing magnetic flux links the secondary winding and induces a voltage across its terminals.

A Complete Guide To Transformer Losses (Core, Copper & Stray)

Step 4: Power is delivered to the load

When a load is connected, secondary current flows and electrical energy is transferred from the primary circuit to the secondary circuit through the magnetic field.

The primary and secondary windings are normally electrically isolated from each other in a conventional transformer, but they are magnetically coupled through the core.

5. Mutual Induction

Mutual induction is the phenomenon in which a changing current in one coil produces a changing magnetic flux that induces an electromotive force (EMF) in another coil.

In a transformer:

  • The primary winding produces changing magnetic flux.
  • The magnetic flux links the secondary winding.
  • The changing flux induces a voltage in the secondary winding.

The induced voltage depends on the rate at which magnetic flux changes and the number of turns in the winding.

Faraday’s law can be written as:

E=−NdΦdtE=-N\frac{d\Phi}{dt}

Where:

  • EE = induced EMF in volts
  • NN = number of turns
  • Φ\Phi = magnetic flux in webers
  • dΦ/dtd\Phi/dt = rate of change of magnetic flux

The minus sign represents Lenz’s law: the induced EMF acts in a direction that opposes the change in magnetic flux that produces it.

6. Types of Transformers

Transformers can be classified according to their function, construction, and application.

A. Step-Up Transformer

What is Faraday's law of induction? | Live Science

livescience.com

A step-up transformer increases AC voltage from the primary side to the secondary side.

It has more turns in the secondary winding than in the primary winding.

Ns>NpN_s>N_p

Therefore:

Vs>VpV_s>V_p

For an ideal transformer, the secondary current is lower than the primary current when the voltage is stepped up.

Example: A transformer increases 12 V AC to 120 V AC.

Common applications include power generation and transmission systems, as well as some electronic circuits.

B. Step-Down Transformer

What is a Step-Down Transformer? | Electronic Design

electronicdesign.com

A step-down transformer decreases AC voltage.

It has fewer turns in the secondary winding than in the primary winding.

Ns\<NpN_s\<N_p

Therefore:

Vs\<VpV_s\<V_p

For an ideal transformer, the secondary current can be greater than the primary current.

Example: A transformer converts 230 V AC to 12 V AC.

Applications include low-voltage power supplies, chargers that use transformer-based designs, and control circuits.

C. Isolation Transformer

What is an Isolation Transformer ? - its Function & Uses

electricalvolt.com

An isolation transformer is designed to provide electrical isolation between the input and output circuits.

In a typical 1:1 isolation transformer:

Np=NsN_p=N_s

Ideally:

Vp=VsV_p=V_s

It is used in test equipment, certain medical and industrial systems, and applications where separation between circuits is required.

Important: An isolation transformer does not automatically make its output safe to touch. Its output can still cause a dangerous electric shock.

D. Autotransformer

Autotransformers - Transformers - Basics Electronics

ecstudiosystems.com

An autotransformer uses a single continuous winding with one or more electrical taps. A portion of the same winding is shared by the input and output circuits.

It can increase or decrease voltage and is often smaller and more economical than a two-winding transformer of comparable rating.

However, it does not provide electrical isolation between the input and output.

Applications include voltage regulators, laboratory variable AC supplies, and certain motor-starting systems.

E. Current Transformer (CT)

Types of Current Transformers

circuitdigest.com

A current transformer is designed to produce a smaller, proportional current for measurement and protection.

It is commonly used to measure large currents in power systems.

For example, a CT with a ratio of 100:5 ideally produces 5 A in its secondary when the primary current is 100 A under its rated conditions.

Safety warning: A conventional current transformer's secondary must not be left open-circuit while primary current flows. A dangerously high secondary voltage may develop.

F. Potential Transformer (PT) or Voltage Transformer (VT)

A potential transformer reduces a high AC voltage to a lower, proportional voltage suitable for meters and protection equipment.

For example, a suitably rated voltage transformer may convert a high system voltage into a standard measurement voltage.

It is commonly used in substations, switchgear, and electrical measurement systems.

G. High-Frequency Transformer

High-frequency transformers operate at frequencies much higher than the usual 50 Hz or 60 Hz power frequency.

They often use ferrite cores to reduce magnetic losses at high frequencies.

Applications include:

  • Switch-mode power supplies (SMPS)
  • DC-DC converters
  • Electronic inverters
  • Telecommunications equipment

7. Transformer Turns Ratio

The turns ratio describes the relationship between the number of turns in the primary and secondary windings.

For an ideal transformer:

VsVp=NsNp\frac{V_s}{V_p}=\frac{N_s}{N_p}

Where:

  • VpV_p = primary voltage
  • VsV_s = secondary voltage
  • NpN_p = primary turns
  • NsN_s = secondary turns

This formula shows that voltage is proportional to the number of winding turns.

Example

Suppose a transformer has:

  • Primary voltage = 230 V
  • Primary turns = 1,000
  • Secondary turns = 100

Calculate the secondary voltage.

Using the turns-ratio formula:

Vs230=1001000\frac{V_s}{230}=\frac{100}{1000} Vs=230×1001000V_s=230\times\frac{100}{1000} Vs=23 V\boxed{V_s=23\text{ V}}

The transformer ideally converts 230 V AC into 23 V AC.

8. Relationship Between Voltage and Current

For an ideal transformer, input power equals output power:

VpIp=VsIsV_p I_p=V_s I_s

Therefore, the current ratio is inversely proportional to the voltage ratio:

IsIp=VpVs\frac{I_s}{I_p}=\frac{V_p}{V_s}

Where:

  • IpI_p = primary current
  • IsI_s = secondary current

This means that when a transformer increases voltage, it decreases current for the same transferred power. When it decreases voltage, it increases current, assuming ideal operation and the same power transfer.

Example

A transformer steps down 230 V AC to 23 V AC. If the primary current is 0.5 A, calculate the ideal secondary current.

230×0.5=23×Is230\times0.5=23\times I_s Is=11523I_s=\frac{115}{23} Is=5 A\boxed{I_s=5\text{ A}}

The primary input power and secondary output power are both 115 VA in this ideal example.

9. Transformer Power Rating

Transformers are commonly rated in VA (volt-amperes) or kVA (kilovolt-amperes) rather than only in watts.

For a single-phase transformer:

S=VIS=VI

Where:

  • SS = apparent power in VA
  • VV = RMS voltage in volts
  • II = RMS current in amperes

For example, a 12 V, 2 A transformer has a nominal apparent-power rating of:

S=12×2=24 VAS=12\times2=24\text{ VA}

This means it is rated for 24 VA under its specified operating conditions.

The actual real power in watts depends on the load's power factor. For a resistive load, watts and VA are approximately equal; for other loads, they may differ.

10. EMF Equation of a Transformer

For a sinusoidal supply, the RMS induced voltage in a transformer winding is:

E=4.44fNΦ_max⁡E=4.44fN\Phi\_{\max}

Where:

  • EE = RMS induced EMF in volts
  • ff = supply frequency in hertz
  • NN = number of turns
  • Φ_max⁡\Phi\_{\max} = maximum magnetic flux in webers

For the primary winding:

Ep=4.44fNpΦ_max⁡E_p=4.44fN_p\Phi\_{\max}

For the secondary winding:

Es=4.44fNsΦ_max⁡E_s=4.44fN_s\Phi\_{\max}

Since both windings link approximately the same magnetic flux, their induced voltages are proportional to their number of turns.

This is the physical basis of the transformer turns-ratio equation.

11. Ideal Transformer vs. Practical Transformer

An ideal transformer is a theoretical model. A practical transformer has losses and other imperfections.

FeatureIdeal transformerPractical transformer
Winding resistanceZeroSmall but nonzero
Core lossesZeroPresent
Leakage fluxNonePresent
Efficiency100%Less than 100%
Output powerEquals input powerLower than input power
Voltage regulationPerfectSome voltage drop under load

Real transformers are designed to reduce losses, improve efficiency, and maintain a stable output voltage.

12. Losses in a Transformer

Some of the input energy is converted into heat and other losses.

A. Copper Loss

Copper loss occurs because the primary and secondary windings have electrical resistance.

It is calculated using:

P_cu=Ip2Rp+Is2RsP\_{\text{cu}}=I_p^2R_p+I_s^2R_s

Higher winding current generally increases copper loss. Using suitable conductor sizes reduces resistance and heating.

B. Hysteresis Loss

Hysteresis loss occurs as the magnetic core repeatedly magnetizes and demagnetizes during AC operation.

It can be reduced by choosing suitable magnetic core materials.

C. Eddy Current Loss

Changing magnetic flux can induce circulating currents inside a conductive core. These currents produce heat.

Transformer cores are often laminated to reduce eddy current losses. High-frequency transformers commonly use suitable high-resistivity core materials such as ferrite.

D. Leakage Flux

Not all magnetic flux produced by the primary winding links the secondary winding. This is called leakage flux.

It affects voltage regulation and transformer performance.

E. Other Losses

Large transformers may also experience stray-load losses, dielectric losses, and losses associated with cooling equipment.

13. Transformer Efficiency

Transformer efficiency describes how much input power is delivered to the output as useful power.

η=P_outP_in×100%\eta=\frac{P\_{\text{out}}}{P\_{\text{in}}}\times100\%

Where:

  • η\eta = efficiency
  • P_outP\_{\text{out}} = output power in watts
  • P_inP\_{\text{in}} = input power in watts

Example

Suppose a transformer receives 500 W and delivers 475 W to the load.

η=475500×100%\eta=\frac{475}{500}\times100\% η=95%\boxed{\eta=95\%}

The remaining 25 W is lost within the transformer and its associated components.

14. Voltage Regulation

Voltage regulation describes how the secondary voltage changes when the load changes from no-load to a specified load condition.

A common definition is:

%VR=V_no-load−V_full-loadV_full-load×100%\%\text{VR}= \frac{V\_{\text{no-load}}-V\_{\text{full-load}}} {V\_{\text{full-load}}}\times100\%

For example, if the no-load secondary voltage is 12.5 V and the full-load voltage is 12 V:

%VR=12.5−1212×100%\%\text{VR}=\frac{12.5-12}{12}\times100\% %VR≈4.17%\boxed{\%\text{VR}\approx4.17\%}

Lower voltage regulation generally indicates that the transformer maintains its output voltage more consistently as the load changes.

15. Why Transformers Do Not Normally Work on DC

A conventional transformer relies on changing magnetic flux to induce voltage in its secondary winding.

With steady DC, after the initial switching transient, the magnetic flux becomes approximately constant. Therefore, no continuous secondary voltage is induced.

There is another important issue: with DC, the primary winding's inductive reactance is absent in steady state. The current may become very large, limited mainly by winding resistance and the supply, potentially causing overheating or damage.

For this reason, never connect a conventional AC transformer directly to a DC supply unless the equipment is specifically designed for that operation.

Electronic converters can transform DC voltage, but they first switch the DC to produce a changing waveform, often at high frequency, which can then operate a transformer.

16. Transformer Frequency

The frequency of the secondary AC voltage is the same as the primary supply frequency in a conventional transformer.

fs=fp\boxed{f_s=f_p}

For example, a 50 Hz AC supply produces a 50 Hz secondary voltage.

A transformer changes voltage and current according to its turns ratio, but it does not directly convert 50 Hz AC to 60 Hz AC. Frequency conversion requires additional electronic or electromechanical equipment.

17. Applications of Transformers

Transformers are used throughout electrical and electronic systems.

Transformer Shortage Crisis: Can New Engineering Solve It? - IEEE Spectrum

Power generation and transmission

Step-up transformers raise voltage for long-distance transmission, helping reduce current and resistive losses for a given transmitted power.

11kv Pole Mounted Equipment - Reliable Power Solutions

Electrical distribution

Distribution transformers reduce the voltage to levels appropriate for local distribution systems and consumers.

FBI XL-2 Alarm

Electronic power supplies

Transformers provide voltage conversion and, in suitable designs, isolation for electronic equipment.

UniGear ZS1 apparatus commutatorius aeris insulatus pro applicationibus electricitatis / Unitas Circuli Principalis - IEE-Business

Measurement and protection

Current and voltage transformers allow electrical meters and protective relays to monitor high currents and voltages.

Radford STA 25 Series 3 Endstufe - Audio Geräte gebraucht kaufen – High End Hifi bei CJM-Audio

Audio and communication systems

Special transformers can provide impedance matching, isolation, and signal coupling in audio and communication circuits.

18. Transformer Safety

Transformers can operate at dangerous voltages and temperatures. Important safety considerations include:

  • Never touch exposed terminals of an energized transformer.
  • Use a transformer with the correct voltage, frequency, and power rating.
  • Provide appropriate overcurrent protection.
  • Ensure adequate ventilation and cooling.
  • Do not use a damaged transformer or one with deteriorated insulation.
  • Do not assume that a low-voltage secondary is safe under every condition.
  • Never leave a conventional current transformer secondary open while primary current flows.

For mains-powered projects, use properly rated equipment, suitable enclosures, and appropriate isolation and protection.

19. Summary of Important Transformer Formulas

QuantityFormula
Turns ratioVsVp=NsNp\frac{V_s}{V_p}=\frac{N_s}{N_p}
Ideal powerVpIp=VsIsV_pI_p=V_sI_s
Current ratioIsIp=VpVs\frac{I_s}{I_p}=\frac{V_p}{V_s}
Apparent powerS=VIS=VI
EMF equationE=4.44fNΦ_max⁡E=4.44fN\Phi\_{\max}
Efficiencyη=P_outP_in×100%\eta=\frac{P\_{\text{out}}}{P\_{\text{in}}}\times100\%
Copper lossP_cu=Ip2Rp+Is2RsP\_{\text{cu}}=I_p^2R_p+I_s^2R_s
Frequency relationshipfs=fpf_s=f_p

In conclusion: A transformer is a fundamental electrical device that transfers AC energy through electromagnetic induction. Its turns ratio determines whether it steps voltage up or down, while its current relationship follows the principle of power conservation. Transformers are essential in power transmission, electrical distribution, electronic power supplies, measurement systems, and electrical isolation.

Keep learning. Keep building. Keep growing.

© 2026 Ugenz Academy